Function Parameter Table VD560 Series Inverter User Manual
- 70 -
FA-22
PID Initial Value
Hold Time
0.00s~650.00s
0.00s
○
FA-23
Twice Output
Deviation
Positive
Maximum
0.00%~100.00%
1.00%
○
FA-24
Twice Output
Deviation
Reverse
Maximum
0.00%~100.00%
1.00%
○
FA-25
PID Integral
Property
Unit’s digit: integral separation
0: Disabled
1: Enabled
Ten’s digit: whether stop integral after
output the limit
0x00
○
FA-26
PID Feedback
Lost Detection
Value
0.0%: Don’t judge feedback lost
0.1%~100.0%
0.0%
○
FA-27
PID Feedback
Lost Detection
Time
0.0s~20.0s
0.0s
○
FA-28
PID Feedback
Lost Detection
Starting
Frequency
0.00Hz~max frequency
10.00Hz
○
FA-29
PID Stop
Operation
0: No operation when stop
1: Operation when stop
0
○
FA-30
The Lower Limit
Value of
Feedback when
PID Action
0.0%: No limit
0.1%~100.0%
0.0.%
○
Fb Enhance Function Group
Function
Code
Parameter
Name
Setting Range
Factory
Default
Value
Property
Fb-00
Jog Running
Frequency
0.00Hz~max frequency
5.00Hz
○
Fb-01
Jog Acceleration
Time
0.0s~6500.0s
Model
dependent
○
Fb-02
Jog Deceleration
Time
0.0s~6500.0s
Model
dependent
○
Fb-03
Acceleration
Time 2
0.0s~6500.0s
Model
dependent
○
Fb-04
Deceleration
Time 2
0.0s~6500.0s
Model
dependent
○