VD560 Series Inverter User Manual Function Parameter Table
- 79 -
Fd-01
Data Format
0: No verify(8-N-2)
1: Even verify(8-E-1)
2: Odd verify(8-O-1)
3: 8-N-1
0
○
Fd-02
Local Address
0~247, 0 is broadcast address
1
○
Fd-03
Response Delay
0ms~200ms
2ms
○
Fd-04
Communication
Timeout Time
0.0 (disabled), 0.1s~60.0s
0.0s
○
Fd-05
Data Transfer
Format
Selection
0: Non standard MODBUS protocol
1: Standard MODBUS protocol
1
○
Fd-06
Communication
Read Current
Resolution
0: 0.01A
1: 0.1A
0
○
FF User Parameters Group
Function
Code
Parameter
Name
Setting Range
Factory
Default
Value
Property
FF-00
User Password
0:~65535
0
○
FF-01
Parameter
Initialization
0: No operation
1: Restore factory default setup value,
exclude of motor parameter
2: Clear the record information
3: Backup user current parameters
4: Restore user current parameters
0
◎
FF-03
Function Code
Display
Selection
Unit’s digit:
0: Not display A group
1: Display A group
Ten’s digit:
0: Not display b group
1: Display b group
0x11
○
FF-04
Function Code
Modify Property
0: Can modify
1: Can’t modify
0
○
FF-05
Fast Debugging
Setting
Unit’s digit: user custom parameter group
display selection
0: Not display
1: Display
Ten’s digit: user change parameter group
display selection
0: Not display
1: Display
0x10
○