VD560 Series Inverter User Manual Parameter Description
- 151 -
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Ten thousand’s digit: communication
abnormal (18)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
F9-37
Fault Protection Action
Selection 2
Unit’s digit: encoder / PG card abnormal
(31)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Ten’s digit: parameter read-write
abnormal (21)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Hundred’s digit: running time reached
(27)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Thousand’s digit: speed deviation is too
larg (40)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Ten thousand’s digit: motor overspeed
(41)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
0x000
00
○
F9-38
Fault Protection Action
Selection 3
Unit’s digit: user-defined fault 1 (35)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Ten’s digit: user-defined fault 1 (36)
0: Coast to stop
1: Stop according to stop mode
2: Continue to run
Hundred’s digit: power on time reached
(28)
0: Coast to stop
1: Stop according to stop mode
0x000
00
○