VD560 Series Inverter User Manual Parameter Description
- 133 -
F5-40
Corresponding Setting of
Pulse Max Input
-100.0%~+100.0%
100.0%
○
F5-41
PULSE Filter Time
0.00s~10.00s
0.10s
○
The group function code is used to set the relationship between HDI1 pulse frequency set and
corresponding setting.
Pulse frequency can only be input into the inverter through the HDI1 channel.
The application of the group is simlar to the curve 1, please refer to the instructions of curve 1.
F5-42
Travel Switch Lock Time
0.00s~10.00s
1.00s
○
It used to terminal control operation mode 5 (back and forth control), please refer to the specific
instructions of back and forth control mode.
F5-43
AI2 Input Type
0: Voltage
1: Current
0
○
F5-44
AI3 Input Type
0: Voltage
1: Current
0
○
AI1 and AI2 have two modes of voltage and current intput, the corresponding output type of hardware
selection, the corresponding parameters are selection of the same type.