Function Parameter Table VD560 Series Inverter User Manual
- 54 -
Hundred’s digit: DI3, same as above
Thousand’s digit: DI4, same as above
Ten thousand’s digit: DI5, same as above
F5-11
DI1 Terminal
Mode Selection
2 Effectively
Unit’s digit: HDI1
0: High level effective
1: Low level effective
Ten’s digit: reserved
Hundred’s digit: reserved
Thousand’s digit: reserved
0x0000
◎
F5-12
DI Filter Time
0.000s~1.000s
0.010s
○
F5-13
DI1 Close Delay
Time
0.0s~3600.0s
0.0s
◎
F5-14
DI2 Close Delay
Time
0.0s~3600.0s
0.0s
◎
F5-15
DI3 Close Delay
Time
0.0s~3600.0s
0.0s
◎
F5-16
DI1 Open Delay
Time
0.0s~3600.0s
0.0s
◎
F5-17
DI2 Open Delay
Time
0.0s~3600.0s
0.0s
◎
F5-18
DI3 Open Delay
Time
0.0s~3600.0s
0.0s
◎
F5-19
Terminal
UP/DOWN
change rate
0.001Hz/s~65.535Hz/s
1.000Hz/s
○
F5-20
AI Curve
Selection
Unit’s digit: AI1 curve selection
1: Curve 1 (2 point, see F5-22~F5-26)
2: Curve 2 (2 point, see F5-27~F5-31)
3: Curve 3 (2 point, see F5-32~F5-36)
4: Curve 4 (4 point, see b2~00-b2-07)
5: Curve 5 (4 point, see b2-08~b2-15)
Ten’s digit: AI2 curve selection, same as
above
Hundred’s digit: AI3 (expansion card)
curve selection, same as above
0x321
○
F5-21
AI is Lower than
Min Input Set
Selection
Unit’s digit: AI1 is lower than min input
setting selection
0: Corresponding to the min input set
1: 0.0%
Ten’s digit: AI2 is lower than min input
setting selection, same as above
Hundred’s digit: AI3 is lower than min
input setting selection, same as above
0X000
○