VD560 Series Inverter User Manual Parameter Description
- 105 -
1: Digital setting frequency
2: AI1
3: AI2
4: AI3 (expansion card)
5: PULSE setting
6: MS reference
7: Simple PLC
8: PID
9: Communication setting
Ten’s digit: terminal command binding
frequency source selection, same as above
Hundred’s digit: communication command
binding frequency source selection, same as
above
Thousand’s digit: Automatic operation
command binding frequency source
selection, same as above
Define the bound combination between three run command channel and nine kinds of frequency
given channel, convenient to realize synchronous switch.
The meaning of the above frequency for given channel is same with the main frequency source X
selection F0-02, please see the description of F0-02 function code.
The different run command channels can be bound to the same frequency given channel.
When the command source has bundled frequency source, during the effective period of this
command source, the set frequency source of F0-02~F0-07 is no longer work.
F0-23
Communication
Protocol Selection
0: Modbus
1: Profibus-DP
2: CANopen
0
●
VD560 provides 3 kinds of communication, these 3 kinds of communication are reired select a
communication card can be used, and 3 kinds of communication can’t be used at the same time.
This parameter is used to set the type of communication, and the parameter must be set correctly
when the user changes the communication card.
F0-24
Motor Selection
0: Motor 1
1: Motor 2
0
◎
VD560 supports the application of frequency inverter time-sharing drag 2 motor respectively,
electrical motor nameplate parameters can be set respectively by 2 motor, independent parameters
tuning, select different control modes, independent setting parameters related to run performance etc.
Motor 1 corresponding function parameter is F2 and F3 group, motor 2 corresponding function
parameter A3 group.
The user through the F0-24 function code to select current motor, also can through the digital
quantity input terminals DI switch motor. When function code selection and terminal selection
contradiction, the terminal selection shall prevail.
F0-25
GP Type Selection
1: G type (constant torque load model)
2: P type (fan, pump type load models)
1
◎
1: Suitable for the constant torque load of specified rated parameters.
2: Suitable for the variable torque load of specified rated parameters.