Equipment Configuration Settings for Rate Control
If you are using an operating configuration with Rate
Control, (such as for certain DirectCommand and
SeedCommand configurations) you must specify
Equipment Configuration Settings. At the
Configuration Setup screen, press the Configuration
Settings button. The Equipment Configuration
Settings screen appears.
These settings are directly related to that specific combination of Vehicle, Implement, and Controller.
• The configuration name can be changed by pressing
.
• The
Rate Outside of Field
selection determines product control channel behavior when the field
boundary is exited.
-
Zero Product
- Product application will turn off.
-
Last Good
- Product application will continue at the last value used by the control system.
-
Rx Default
- Product will be applied at the default rate setting.
• Rate Display Smoothing setting
Determines how the feedback from the control channel rate sensor will be displayed on the map screen.
When de-selected, the system will display raw feedback from the rate sensor. When checked, the system
will display target rate when the application rate is within 10% of the target rate setting.
• Controller Time Delay setting
Compensates for any latency in the control system when changing between different product flow rates
during variable rate application. The typical setting range for this is 0 - 1 seconds.
S
PEED
I
NPUT
S
ETTINGS
Press: Home button > Setup (wrench) button > Configuration (tractor) button > Configuration tab > your
specific configuration > Setup (wrench) button > Speed Input button
Equipment Configuration Settings
Rate Outside of Field
Rate Display
Smoothing
0 sec
Controller
Time Delay
Zero
Configuration
Your Specific
Configuration
Speed
Input
Summary of Contents for ag leader
Page 1: ...Operators Manual Firmware Version 5 4 Ag Leader PN 4002722 Rev G ...
Page 2: ...Firmware Version 5 4 ...
Page 20: ...6 Firmware Version 5 4 ...
Page 38: ...24 Firmware Version 5 4 For more information see Legend Settings on page 52 ...
Page 55: ...41 SETUP M ANAGEMENT S ETUP Remove button Press to remove a business ...
Page 56: ...42 Firmware Version 5 4 ...
Page 78: ...64 Firmware Version 5 4 ...
Page 82: ...68 Firmware Version 5 4 Press to Export All Log files Export All Log Files ...
Page 84: ...70 Firmware Version 5 4 ...
Page 94: ...80 Firmware Version 5 4 ...
Page 108: ...94 Firmware Version 5 4 ...
Page 140: ...126 Firmware Version 5 4 ...
Page 154: ...140 Firmware Version 5 4 ...
Page 158: ...144 Firmware Version 5 4 ...
Page 162: ...148 Firmware Version 5 4 ...
Page 222: ...208 Firmware Version 5 4 ...
Page 244: ...230 Firmware Version 5 4 ...
Page 260: ...246 Firmware Version 5 4 ...
Page 290: ...276 Firmware Version 5 4 ...
Page 304: ...290 Firmware Version 5 4 ...