164
Firmware Version 5.4
• Make sure seed meter is primed. For more information, See
above.
Press: Map button > Meter RPM button > Planter Drives > Calibrate button
1. Acknowledge the Warning
Acknowledge this warning by pressing
.
2. Select Drive to Calibrate
The Meter Calibration Wizard appears. Select the drive to calibrate. Press
to continue.
3. Enter Simulated Ground Speed
Enter the simulated ground speed for the calibration procedure. Press
to continue.
4. Enter Simulated Target Rate
Enter the simulated target rate of the calibration procedure. Press
to continue.
5. Press Start
Press the green-colored Start button to begin dispensing the seed.
6. Dispensing Seed
The seed meter turns for five revolutions. As the seed meter dispenses seed, the button will change its color
to red, and a message displays that the seed dispensation is in process.
7. Seed Dispensing Complete
When the meter is finished dispensing seed, the button will change back to its original green color, and will
once again display the word Start. Press
to continue.
8. Enter Number of Dispensed Seeds
Press
to enter the number of dispensed seeds. Press
to continue.
Note: The meter calibration will be calculated from the actual seed amount dispensed.
R
ATE
C
ONTROL
: M
AP
S
CREEN
The map screen displays a twosection SeedCommand
configuration running a Variable Rate Control configuration
that includes three Hydraulic Seed drives, and also Row
Shutoff with AutoSwath. Because the configuration is for a
split-planting operation with three varieties, these three
varieties are shown with different colors on the map.
Planter Drives (rpm)
1
70
Planter Drives
Calibrate
40 ft 0 in
sds/ac
32000
sds/ac
30000
30000
30000
30000
32000
38.4
ac
Flow: 5280 sds/min
1
2
92B12
S46R1
40 ft 0 in 100%
Varieties
Corn
C1966
C1291
Planter Drives (rpm)
1
2
110
104
100%
Summary of Contents for ag leader
Page 1: ...Operators Manual Firmware Version 5 4 Ag Leader PN 4002722 Rev G ...
Page 2: ...Firmware Version 5 4 ...
Page 20: ...6 Firmware Version 5 4 ...
Page 38: ...24 Firmware Version 5 4 For more information see Legend Settings on page 52 ...
Page 55: ...41 SETUP M ANAGEMENT S ETUP Remove button Press to remove a business ...
Page 56: ...42 Firmware Version 5 4 ...
Page 78: ...64 Firmware Version 5 4 ...
Page 82: ...68 Firmware Version 5 4 Press to Export All Log files Export All Log Files ...
Page 84: ...70 Firmware Version 5 4 ...
Page 94: ...80 Firmware Version 5 4 ...
Page 108: ...94 Firmware Version 5 4 ...
Page 140: ...126 Firmware Version 5 4 ...
Page 154: ...140 Firmware Version 5 4 ...
Page 158: ...144 Firmware Version 5 4 ...
Page 162: ...148 Firmware Version 5 4 ...
Page 222: ...208 Firmware Version 5 4 ...
Page 244: ...230 Firmware Version 5 4 ...
Page 260: ...246 Firmware Version 5 4 ...
Page 290: ...276 Firmware Version 5 4 ...
Page 304: ...290 Firmware Version 5 4 ...