168
Firmware Version 5.4
d. Switch the Master Switch on.
e. Press the up button one time. Now press the down button one time. The drive should be turning. If
not, repeat this procedure starting with Step b.
H
YDRAULIC
S
EED
C
ONTROL
: Z
ERO
F
LOW
O
FFSET
V
ARIATION
Error Message:
Hydraulic drive not shutting off properly, or minimum controllable speed is greater than
specified.
Possible Cause:
Zero Flow Offset is set too high.
Confirmation Technique:
a. Turn the Master Switch off. Enter a manual ground speed and create a new region.
b. From the Run screen, open the product application rate window, and highlight the appropriate
product. Select Manual control mode.
c. Switch the Master Switch on.
d. Press the up button one time. Now press the down button three times. If the drive is still turning, the
zero flow offset is likely to be too high.
Solution:
a. Turn the Master Switch off. Enter a manual ground speed and enter a new region.
b. Reduce Zero Flow Offset by 2.
c. From the Run screen, open the product application rate window, and highlight the appropriate
product. Select Manual control mode.
d. Switch the Master Switch on.
e. Press the up button one time. Now press the down button three times. The drive should not be
turning. If it is, repeat this procedure, starting with step b.
Note: Zero Flow Offset should never be less than 25. If 25 still seems as if this number is too high, there must
be some other problem. Contact Technical Support for further assistance.
S
TEPPER
S
EED
C
ONTROL
M
ETER
A
LARMS
Error Message:
“Drive Out of Synch Error Drive #”
Possible Cause:
Not enough hydraulic fluid is flowing to the seed meter.
Solution:
Examine the stepper seed drive’s hydraulic components for restrictions. Make
sure the tractor’s hydraulic outlet is turned on. Make sure the hydraulic flow settings are
correct.
Error Message:
“Drive Stalled Drive #”
Possible Cause:
The hydraulic drive motor has stopped rotating.
Solution:
Check the stepper seed motor to see if it is restricted from turning, and that the
hydraulic drive is working.
Error Message:
“Meter Not Moving - Drive #”
Possible Cause:
Either the Seed Meter Calibration failed, or the Seed Meter Prime failed
Solution:
Make sure that the tractor’s hydraulic outlet is turned on.
Error Message:
“Seed Drive at Maximum RPM Drive #”
Possible Cause:
Starting the priming routine when the hydraulic motor is not on
Solution:
- Slow the planter unit’s ground speed. - Reduce the Planting Target Rate.
Summary of Contents for ag leader
Page 1: ...Operators Manual Firmware Version 5 4 Ag Leader PN 4002722 Rev G ...
Page 2: ...Firmware Version 5 4 ...
Page 20: ...6 Firmware Version 5 4 ...
Page 38: ...24 Firmware Version 5 4 For more information see Legend Settings on page 52 ...
Page 55: ...41 SETUP M ANAGEMENT S ETUP Remove button Press to remove a business ...
Page 56: ...42 Firmware Version 5 4 ...
Page 78: ...64 Firmware Version 5 4 ...
Page 82: ...68 Firmware Version 5 4 Press to Export All Log files Export All Log Files ...
Page 84: ...70 Firmware Version 5 4 ...
Page 94: ...80 Firmware Version 5 4 ...
Page 108: ...94 Firmware Version 5 4 ...
Page 140: ...126 Firmware Version 5 4 ...
Page 154: ...140 Firmware Version 5 4 ...
Page 158: ...144 Firmware Version 5 4 ...
Page 162: ...148 Firmware Version 5 4 ...
Page 222: ...208 Firmware Version 5 4 ...
Page 244: ...230 Firmware Version 5 4 ...
Page 260: ...246 Firmware Version 5 4 ...
Page 290: ...276 Firmware Version 5 4 ...
Page 304: ...290 Firmware Version 5 4 ...