203
A
PPLICATION
L
IQU
ID
R
ATE
C
ONTROL
• Allowable Error
Default Value: 2%
2% - 3% is the normal dead band setting range.
- Too low of a setting value can cause the product control system to continually hunt for the target
application rate.
- Too high of a setting will cause excessive product application error.
D
ICKEY
-J
OHN
NH3 C
ONVERSIONS
Conversion Formulas
The following formulas can be used to convert the Dickey John flow sensor constant to a value that
represents pulses/gallon of anhydrous ammonia for use by the display.
Note: The flow sensor constant is tagged on the Dickey-John flow meter. The density setting comes from a
chart in the Dickey-John documentation and is not provided in this manual.
T
ROUBLESHOOTING
S
ERIAL
C
ONTROL
A
PPLICATIONS
Problem:
Rate changes on the display, but not on the controlled console.
Solution:
1. Verify the current firmware is running on the display and Application Rate module.
2. Check the settings specific to your controlled console. (For more information, refer to the Quick
Reference Guide).
3. Check cabling and all connections.
4. Disconnect the serial connection and determine if the controller is functioning properly without
the display.
Problem:
The display rate and serial-controlled rate do not match.
Solution:
1. Verify the current firmware is running on the display and the Application Rate Module.
2. Check the percent rate change. (Refer to the Quick Reference Guide for more information).
Conversion Formula
Formula for flow meter calibration for Dickey John reading pounds of anhydrous
Flow sensor constant (pulses/in
3
) X 1728 (in
3
/ft
3
) X 5.11 (lbs of anhydrous/gal)
Solution: Density (lbs. of anhydrous/ft
3
)
Formula for flow meter calibration for Dickey John reading pounds of Nitrogen
Flow sensor constant (pulses/in
3
) X 1728 (in
3
/ft
3
) X 4.22 (lbs of N/gal)
Density (lbs. of N/ft
3
)
Summary of Contents for ag leader
Page 1: ...Operators Manual Firmware Version 5 4 Ag Leader PN 4002722 Rev G ...
Page 2: ...Firmware Version 5 4 ...
Page 20: ...6 Firmware Version 5 4 ...
Page 38: ...24 Firmware Version 5 4 For more information see Legend Settings on page 52 ...
Page 55: ...41 SETUP M ANAGEMENT S ETUP Remove button Press to remove a business ...
Page 56: ...42 Firmware Version 5 4 ...
Page 78: ...64 Firmware Version 5 4 ...
Page 82: ...68 Firmware Version 5 4 Press to Export All Log files Export All Log Files ...
Page 84: ...70 Firmware Version 5 4 ...
Page 94: ...80 Firmware Version 5 4 ...
Page 108: ...94 Firmware Version 5 4 ...
Page 140: ...126 Firmware Version 5 4 ...
Page 154: ...140 Firmware Version 5 4 ...
Page 158: ...144 Firmware Version 5 4 ...
Page 162: ...148 Firmware Version 5 4 ...
Page 222: ...208 Firmware Version 5 4 ...
Page 244: ...230 Firmware Version 5 4 ...
Page 260: ...246 Firmware Version 5 4 ...
Page 290: ...276 Firmware Version 5 4 ...
Page 304: ...290 Firmware Version 5 4 ...