15.SPECIFICATIONS
149
15-3. Interface
CC-Link interface
(Serial bus interface for connection with Mitsubishi PLC as the remote device stations
corresponding to CC-Link Ver.1.10.)
Transmission medium: 3-wire type (shielded)
Transmission speed:
Selectable from 156K/625K/2.5M/5M/10Mbps
RS-232C interface
Weight data, various statuses, and various set values can be written and read by commands from
the host side.
(Exclusively used with setting remote console unit C110 or C120)
Specifications:
RS-232C-based
Transmission method:
Full duplex/start-stop method
Transmission speed:
Selectable from
1200 / 2400 / 4800 / 9600 / 19200 / 38400 bps
Format:
Data length:
7/8 bit
Stop bit length:
1/2 bit
Parity bit:
Odd / Even / None
SI/F 2-wire serial interface
This is a simple output serial interface for connection of a UNIPULSE-manufactured printer,
external display, etc.
Transmission method:
Start-stop method
Transmission speed:
600 bps
15-4. General performance
Power supply voltage
Selectable from
85 – 110V/102 – 132V/170 – 220V/187 – 242V AC.
Power consumption
50/60Hz 13.0/12.5VA (when 100V is rated)
Dimensions
67W×185H×130D (mm)
(excluding projections)
Operating conditions
Temperature:
Operating temperature range:-10 to +40
℃
Storage temperature range: -20 to +80
℃
Humidity:
85%RH or less (non-condensing)
Weight
Approximately 1.7kg
Summary of Contents for F156
Page 1: ...F156 WEIGHING CONTROLLER 07 JUN 2012 REV 1 40 OPERATION MANUAL CC Link Ver 1 10...
Page 115: ...7 REMOTE CONSOLE UNIT 106 Monitor change Change the display with the key...
Page 120: ...7 REMOTE CONSOLE UNIT 111 Monitor change Change the display with the keys 0 to 9 1 2 3 4 5 0...
Page 155: ...13 DIMENSIONS 146 13 DIMENSIONS...