8.EXTERNAL INPUT/OUTPUT (Amphenol Connector)
117
8. EXTERNAL INPUT/OUTPUT
(Amphenol Connector)
The external input/output signals are selective.
Select necessary signals and set them to each port.
However, in the case of redundant settings to input signals, operation is performed as follows:
- For the timing of edge operation
Functional operation is performed at the edge of any of the input ports assigned with the
same signal.
- For the timing of level operation
The port the largest in number among the input ports assigned with the same signal becomes
valid.
8-1. Connector Pin Assignments
Output assignments
Output allocation
Pin No.
Port
Setting code
Initially-specified signal
1
COM (Output power GND)
2
External control output 0
60
01 (SP1)
3
External control output 1
61
02 (SP2)
4
External control output 2
62
03 (SP3)
5
External control output 3
63
04 (Under)
6
External control output 4
64
05 (Go)
7
External control output 5
65
07 (Complete)
8
COM (Output power GND)
9
External control output 6
66
11 (Stable)
Setting value
Signal
Setting value
Signal
00
Near zero
09
Lower limit
01
SP1
10
Upper limit
02
SP2
11
Stable
03
SP3
12
Weight error
04
Under
13
Sequence error
05
Go
14
Final error
06
Over
15
In operation (RUN)
07
Complete
16
Clock (in an approximately
one-second cycles)
08
Normally OFF
Summary of Contents for F156
Page 1: ...F156 WEIGHING CONTROLLER 07 JUN 2012 REV 1 40 OPERATION MANUAL CC Link Ver 1 10...
Page 115: ...7 REMOTE CONSOLE UNIT 106 Monitor change Change the display with the key...
Page 120: ...7 REMOTE CONSOLE UNIT 111 Monitor change Change the display with the keys 0 to 9 1 2 3 4 5 0...
Page 155: ...13 DIMENSIONS 146 13 DIMENSIONS...