6.FUNCTIONS
100
6-13-5. Relationship between auto zero times, judging times, and auto free
fall compensation
●
When the number of auto zero times is set at 01, auto (digital) zero is applied each time
weighing starts. (For weighing in net weight, tare subtraction is carried out.)
When the number of auto zero times is set at 02 – 99, auto zero is applied for every set times.
When the number of auto zero times is set at 00, the auto zero function is OFF. However,
digital zero and tare subtraction by console key operation, external input signal, and serial
and CC-Link I/F are valid.
●
When the number of judging times is set at 01, judgment is made each time weighing ends.
When the number of judging times is set at 02 – 99, judgment is made every set times.
When the number of judging times is set at 00, over/under comparisons are not made.
●
Since weight values for auto free fall compensation are sampled at judge-time, the auto free
fall compensation function does not work when no judgment is made.
Start
Auto zero
Complete
Judgment
Auto free fall
AZ times
3 times
Judging
2 times
2 times
Average count of auto free
compensation
times
fall compensation
Summary of Contents for F156
Page 1: ...F156 WEIGHING CONTROLLER 07 JUN 2012 REV 1 40 OPERATION MANUAL CC Link Ver 1 10...
Page 115: ...7 REMOTE CONSOLE UNIT 106 Monitor change Change the display with the key...
Page 120: ...7 REMOTE CONSOLE UNIT 111 Monitor change Change the display with the keys 0 to 9 1 2 3 4 5 0...
Page 155: ...13 DIMENSIONS 146 13 DIMENSIONS...