6.FUNCTIONS
85
6-12-10. Complete output mode
Set the timing to output the complete signal.
Parameters that determine the timing are the judging time and stable signal.
Setting
2 : Output by the complete output time after the judging time is up or from when
the weight value has become stable with the SP3 signal ON
1 : Output by the complete output time from when the weight value has become
stable after the judging time is up with the SP3 signal ON
0 : Output by the complete output time after the judging time is up with the SP3
signal ON
CC-Link
0
26
MSB
LSB
RWw0006
RWw0005
RWw0004
Write the code No. and set value.
H
L
0
0 to 2
Word size
remote register
Set value
Code No.
Console
1) Select code 26.
2) Press the ENT key, and then set the
complete output mode.
3) Determine the setting with the ENT key.
Complete output