6.FUNCTIONS
87
Example) Final
20.000
Auto free fall compensation regulation
0.100
Average count of auto free fall compensation
4
Auto free fall compensation coefficient
2/4
Times
Actual weighing
Error
Average count of AFFC.
CPS
0
0
←
Power ON
1
20.050
+0.050
1
0.500
2
20.040
+0.040
2
0.500
3
20.070
+0.070
3
0.500
4
20.080
+0.080
4
→
0
0.500
+0.240/4
=
0.060
0.060
×
2/4
=
0.030
→
CPS value
5
20.020
+0.020
1
0.530
6
20.000
0.000
2
0.530
7
20.010
+0.010
3
0.530
8
20.110
(+0.110)
←×
3
0.530
9
20.010
+0.010
4
→
0
0.530
+0.040/4
=
0.010
0.010
×
2/4
=
0.005
→
CPS value
10
19.880
(-0.120)
←×
1
0.535
11
19.990
-0.010
1
0.535
12
20.010
+0.010
2
0.535
13
20.000
0.000
3
0.535
14
19.980
0.020
4
→
0
0.535
-0.020/4
=
-0.005
-0.005
×
2/4
=
-0.003
→
CPS value
0.532
Compensation coefficient setting
The compensation coefficient can be selected from 1/4, 2/4, 3/4 and 1.
Select 1 for weighing such that each weight value is almost equal, and
select 1/4 - 2/4 for weighing such that each weight value varies, so that a
higher-precision free fall compensation value can be calculated.
Summary of Contents for F156