6.FUNCTIONS
67
(1) By setting external input; Tare subtraction ON, etc., Net weight is zeroed. (Tare subtraction)
(2) The feeding valves are fully opened to start feeding. When the weighed value reaches (Final
- Set Point 1), Set Point 1 output signal turns ON. (If the comparison inhibit timer is set, the
timer starts.) After the timer expires, Set Point 1 valve of the material tank is closed to “Set
Point 2”.
(3) When the weighed value reaches (Final - Set Point 2), Set Point 2 output signal turns ON. (If
the comparison inhibit timer is set, the timer starts.) After the timer expires, Set Point 2
valve of the material tank is closed to “Set Point 3”.
(4) When the weighed value reaches (Final - Compensation), Set Point 3 output signal turns
ON, and if the judging timer is set, the timer starts. The feeding valves are completely
closed.
(5) After the judging timer expires, Over/Under judgment is made. If the weighed value exceeds
the range of the Over/Under setting value, the over signal or under signal turns ON.
(6) Raw materials are discharged from the weighing tank to a container. The valves of the
weighing tank should be opened. Completion of discharge is confirmed with the Near Zero
signal. In weighing from the second time onward, (1) ~ (5) are repeated.
The feeding valves and discharge valves should be opened and closed
through the sequencer or relay sequence according to the control signals from
the F156.
Summary of Contents for F156
Page 1: ...F156 WEIGHING CONTROLLER 07 JUN 2012 REV 1 40 OPERATION MANUAL CC Link Ver 1 10...
Page 115: ...7 REMOTE CONSOLE UNIT 106 Monitor change Change the display with the key...
Page 120: ...7 REMOTE CONSOLE UNIT 111 Monitor change Change the display with the keys 0 to 9 1 2 3 4 5 0...
Page 155: ...13 DIMENSIONS 146 13 DIMENSIONS...