5. Electrical Characteristics
208
Tsi308 User Manual
80D4000_MA001_02
Tundra Semiconductor Corporation
www.tundra.com
5.14
Power Sequencing
The preferred power-on sequence for the Tsi308 is from low voltage to high: +1.2V first, +1.8V
second, then +3.3V. Tracking between the power supplies is not required.
The Tsi308 can be powered up with the higher voltages first, but there will be more current
drawn during the power-up period until the lower voltages reach their steady-state levels.
5.15
Supply Operatiing Ranges
5.16
Absolute Maximum Ratings
Table 33: Supply Operating Ranges
Parameter
Minimum
Typical
Maximum
Unit
3.3V
3.13
3.3
3.46
V
1.8V Analog PLL Power
1.71
1.8
1.89
V
1.8V Core Logic Power
1.71
1.8
1.89
V
1.2V
1.14
1.2
1.26
V
Table 34: Absolute Maximum Ratings
Parameter
Minimum
Typical
Maximum
Unit
3.3V
2.9
3.3
3.7
V
1.8V Analog PLL Power
1.6
1.8
2.0
V
1.8V Core Logic PLL
1.6
1.8
2.0
V
1.2V
1.0
1.2
1.4
V
Stresses beyond those listed above may cause permanent damage to the device.
These are stress ratings only. Functional operation of the device at these or any
other conditions beyond those indicated in the Operating Conditions table is not
implied.
Summary of Contents for TSI308
Page 4: ...4 Tsi308 User Manual 80D4000_MA001_02 Tundra Semiconductor Corporation www tundra com ...
Page 6: ...6 Tsi308 User Manual 80D4000_MA001_02 Tundra Semiconductor Corporation www tundra com ...
Page 20: ...20 Tsi308 User Manual 80D4000_MA001_02 Tundra Semiconductor Corporation www tundra com ...
Page 260: ...Index 260 Tsi308 User Manual 80D4000_MA001_02 Tundra Semiconductor Corporation www tundra com ...