5. Electrical Characteristics
191
Tsi308 User Manual
80D4000_MA001_02
Tundra Semiconductor Corporation
www.tundra.com
5.1.1
AC Timing Values
T
SU
Input set-up. Amount of time before the reference clock edge that the input must be valid.
T
HLD
Input hold. Amount of time after the reference clock edge that the input must remain valid.
T
PW
Pulse width. Amount of time the input or output is active.
Table 24: Typical AC Timing Values
Symbol
Conditions
Bidirectional
Output
Units
Min
Nom
Max
Min
Nom
Max
Frequency
--
DC
100
DC
100
MHz
T
CLK
--
10
DC
10
DC
ns
T
CLKH
--
30
70
30
70
%
T
CLKL
--
30
70
30
70
%
T
RISE
2.2 pF
0.37
0.27
ns
27 pF
2.36
1.83
ns
53 pF
4.74
3.54
ns
78 pF
7.31
5.33
ns
100 pF
9.92
7.13
ns
T
FALL
2.2 pF
0.30
0.25
ns
27 pF
2.30
1.80
ns
53 pF
4.82
3.58
ns
78 pF
7.41
5.36
ns
100 pF
10.0
7.15
ns
T
JITTER
--
500
500
ps
T
DO
--
1
10
1
10
ns
T
ZD
--
10
10
ns
T
DZ
--
5
5
ns
Table 23:
AC Timing Definitions
Symbol
Definition
Summary of Contents for TSI308
Page 4: ...4 Tsi308 User Manual 80D4000_MA001_02 Tundra Semiconductor Corporation www tundra com ...
Page 6: ...6 Tsi308 User Manual 80D4000_MA001_02 Tundra Semiconductor Corporation www tundra com ...
Page 20: ...20 Tsi308 User Manual 80D4000_MA001_02 Tundra Semiconductor Corporation www tundra com ...
Page 260: ...Index 260 Tsi308 User Manual 80D4000_MA001_02 Tundra Semiconductor Corporation www tundra com ...