8
Electrical connection
of the safety/drain
valve
Fig. G:
Connect the valve
with the red continuous cur-
rent cable (+) to the fused ve-
hicle power supply (1 A).
Connect the 2-pin cable with
double connector (54) to the
control unit. The brown cable
(55) is provided for the remote
control of the safety/drain
valve (refer to operating in-
structions - accessories).
12
230 V electrical
connection
(special version)
Attention:
The electrical con-
nection is only to be carried
out by an expert (in Germany,
acc. to VDE 0100, Section 721).
The information given here is
not intended as instructions
for you to carry out. It is for
assisting the expert assigned
to carry out the job, acting as
auxiliary information when
connecting the appliance!
Connection to the mains sup-
ply is effected by means of
cables 3 x 1.5 mm
2
(e.g. hose
line H05VV-F) to a distributor
box (not included in the
scope of supply).
Always make sure to connect
carefully, observing the cor-
rect colours!
For maintenance and repair
work a disconnecting device
must be provided on the vehi-
cle for all-pole disconnection
from the power supply, with
at least 3 mm contact clear-
ance.
Mount splitting box near to
the appliance - on the vehicle
floor or on the wall (length of
cable: 90 cm).
Mount control panel in such a
way that it is not exposed to
direct heat radiation form the
heater (cable length: 2.5 m).
Drill a hole measuring 8 mm
in diameter for the cable
leadthrough, pass the cable
through and fasten control
panel with the two screws.
Connect control panel cable,
230 V cable and heating
collar cable as shown in the
diagram.
1 = Control panel cable
2 = Supply 3 x 1.5 mm
2
3 = Heating collar cable
4 = brown
5 = green
6 = blue
7 = yellow
8 = white
9 = yellow/green
Attention:
All cables must
be secured with cable clips.
13
Function check
After installation, check the
gas supply line for leaks ac-
cording to the pressure drop
method. Then check all func-
tions of the appliance, as speci-
fied in the operating instruc-
tions, in particular the water
content draining function.
There shall be no claims
under guarantee for dam-
age caused by frost!
14
Warning information
The installer or vehicle owner
must apply the yellow sticker
with the warning information,
which is enclosed with the
appliance, to a place in the
vehicle where it is clearly visi-
ble to all users (e.g. on the
wardrobe door)! Ask Truma to
send you stickers, if neces-
sary.