E6581697
K-38
11
Table of output terminal functions 4
Function
No.
Code Function
Action
Reference
144
PIDF
Signal in accordance of frequency command
ON: Frequency commanded by
and
are
within
±
.
OFF: Other than those above
6.3.4
6.20
145
PIDFN
Inversion of signal in accordance of
frequency command
Inversion of PIDF
146
FLR
Fault signal (output also at a retry waiting)
ON: While inverter is tripped or retried
OFF: While inverter is not tripped and not retried
6.15.3
147
FLRN
Inversion of fault signal (output also at a
retry waiting)
Inversion of FLR
150
PTCA
PTC input alarm signal
ON: PTC thermal input value is
f646
or more
OFF: PTC thermal input value is less than
f646
6.24.16
151
PTCAN
Inversion of PTC input alarm signal
Inversion of PTCA
152
STO
Safe torque off signal
ON: Safe torque off signal output
OFF: Other than those above
9.3
153
STON
Inversion of safe torque off signal
Inversion of STO
154
DISK
Analog input break detection alarm
ON: VIB terminal input value is
f633
or less
OFF: VIB terminal input value is more than
f633
6.24.14
155
DISKN
Inversion of analog input break detection
alarm
Inversion of DISK
156
LI1
F terminal status
ON: F terminal is ON status
OFF: F terminal is OFF status
7.2.2
157
LI1N
Inversion of F terminal status
Inversion of LI1
158
LI2
R terminal status
ON: R terminal is ON status
OFF: R terminal is OFF status
159
LI2N
Inversion of R terminal status
Inversion of LI2
160
LTAF
Cooling fan replacement alarm
ON: Cooling fan reaches parts replacement time
OFF: Cooling fan does not reach parts replacement time
6.24.15
161
LTAFN
Inversion of cooling fan replacement alarm
Inversion of LTAF
162
NSA
Number of starting alarm
ON: Number of starting alarm is
f648
or more
OFF: Number of starting alarm is less than
f648
6.24.17
163
NSAN
Inversion of number of starting alarm
Inversion of NSA
166
DACC
Acceleration operation in progress
ON: Acceleration operation in progress
OFF: Other than those above
7.2.2
167 DACCN Inversion
of
acceleration operation in
progress
Inversion of DACC
168
DDEC
Deceleration operation in progress
ON: Deceleration operation in progress
OFF: Other than those above
169 DDECN Inversion
of
deceleration operation in
progress
Inversion of DDEC
170
DRUN
Constant speed operation in progress
ON: Constant speed operation in progress
OFF: Other than those above
171 DRUNN Inversion
of
constant speed operation in
progress
Inversion of DRUN
172
DDC
DC braking in progress
ON: DC braking in progress
OFF: Other than those above
6.8.1
173 DDCN Inversion
of
DC braking in progress
Inversion of DDC
174 to 179
Factory specific coefficient
-
*1
*1: Factory specific coefficient parameters are manufacturer setting parameters. Do not change the value of these parameters.
Summary of Contents for TOSVERT VF-MB1
Page 350: ...2011 07 ...