E6581697
F-2
6
An example of the connection of
the open collector OUT (sink logic)
An example of the connection of
the relay output terminals
Output terminal setting
Default outputs low-speed signal (ON signal) to RY-RC terminal. This setting must be changed to invert
the polarity of the signal.
[Parameter setting]
Title
Function
Adjustment range
Default setting
f130
Output terminal selection 1A (RY-RC)
0-255
(Refer to section 11.7)
4:
LOW (Low-
speed detection
signal)
Setting value 5 is reverse signal.
Note) Set
f132
to output to FLA-FLC-FLB terminals and
f131
to OUT terminal.
6.1.2
Output of designated frequency reach signal
f102
: Speed reach detection band
Function
When
the output frequency becomes equal to the setting by designated frequency
f102
, an ON
or OFF signal is generated.
[Parameter setting]
■
Parameter setting of designated frequency and detection band
Title
Function
Adjustment range
Default setting
f102
Speed reach detection band
0.0-
fh
(Hz)
2.5
■
Parameter setting of output terminal selection
Title
Function
Adjustment range
Default setting
f131
Output terminal
selection 2A (OUT)
0-255
(Refer to section 11.7.)
6: RCH (Output frequency attainment signal
(acceleration/deceleration completed))
Setting value 7 is reverse signal.
Note: Set
f132
to output to FLA-FLC-FLB terminals and
f130
to RY-RC terminal.
+24V
RY
RC
Ry
+24V
OUT
NO
CC
Ry
P24
Summary of Contents for TOSVERT VF-MB1
Page 350: ...2011 07 ...