E6581697
F-116
6
Ex.) When using the S3 terminal as the tracing back trigger signal terminal
Title
Function
Adjustment range
Example of setting
f116
Input terminal function selection 6 (S3)
0-203
76: TRACE (Trace
back trigger signal)
Setting value 77 is reverse signal.
Note 1: If the inverter trips when no trigger signal is given, trace data is overwritten with tripping data.
Note 2: Trace data is overwritten each time a trigger signal is given.
Note 3: When retry operation is occurred, the data at first tripping is written. The trace data is cleared at retry success.
[Setup values of
f742
to
f745
]
Default setting
Communication
No.
Trace (monitor) function
Communication
unit at tracing
0
FD00 Operation
frequency
0.01Hz
1
FD03 Output
current
0.01%
2
FD02
Frequency setting value
0.01Hz
3
FD04
Input voltage (DC detection)
0.01%
4
FD05
Output voltage (command value)
0.01%
5
FD29 Input
power
0.01kW
6
FD30 Output
power
0.01kW
7
FD18 Torque
0.01%
9
FD23
Motor cumulative load factor
0.01%
10
FD24
Inverter cumulative load factor
0.01%
11
FD25
PBR (Braking resistor) cumulative load factor
0.01%
12
FD15
Frequency setting value (after compensation)
0.01Hz
13
FE35
VIA input value
0.01%
14
FE36
VIB input value
0.01%
18
FA51
Arbitrary code from communication
-
20
FE37
VIC input value
0.01%
21
FE56
Pulse train input value
1pps
23
FD22
PID feedback value
0.01Hz
24
FE76 Input
power
1kWh
25
FE77 Output
power
1kWh
26
FE26
Motor load factor
1%
27
FE27 Drive
load
factor
1%
40
FD06
Input terminal status
-
41
FD07
Output terminal status
-
42
FD01 Inverter
status
-
■
Acquisition of trace data
Trace data is acquired through a communication device.