E6581697
K-1
11
11. Table of parameters and data
11.1 Frequency setting parameter
Title Function Unit
Minimum
setting unit
Panel/Comm
unication
Adjustment range
Default setting
User
setting
Reference
Operation
frequency of
operation panel
Hz 0.1/0.01
-
0.0
3.2.2
11.2 Basic
parameters
Five
navigation
functions
Title
Communication
No.
Function Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
-
History function
-
-
Displays parameters in groups of five
in the reverse order to that in which
their settings were changed.
* (Possible to edit)
- 4.3
5.1
0093 Guidance
function
-
- 0:
-
1: -
2: Preset speed guidance
3: Analog signal operation guidance
4: Motor 1 & 2 switching operation
guidance
5: Motor constant setting guidance
0 4.3
5.2
0094 Overload
characteristic
selection
- -
0:
-
1: Constant torque characteristic
(
150%-60s
)
2: Variable torque characteristic
(
120%-60s
)
0 3.5
5.3
6.14
0000 Automatic
acceleration/
deceleration
-
-
0: Disabled (manual setting)
1: Automatic
2: Automatic (only at acceleration)
0 5.4
0001 Torque
boost
setting macro
function
- -
0:
-
1: Automatic torque boost + auto-
tuning
2: Vector c auto-tuning
3: Energy auto-tuning
0 5.5
Summary of Contents for TOSVERT VF-MB1
Page 350: ...2011 07 ...