6.31 Integrating wattmeter
f748
: Integrating wattmeter retention selection
f749
: Integrating wattmeter display unit selection
Function
At the main power off ,it is selectable whether retention of integral output power values or not.
And also, the display unit is selectable.
The integrating wattmeter display can be cleared by external input signal by assignment of the terminal
function. Input terminal function 74, 75 (Integrating wattmeter display clear)
Title
Function
Adjustment range
Default setting
f748
Integrating wattmeter retention selection
0: Disabled
1: Enabled
0
f749
Integrating wattmeter display unit selection
0:1=1kWh
1:1=10kWh
2:1=100kWh
3:1=1000kWh
Depends on
the capacity
(Refer to
section 11.4)
6.32 Parameter registration to easy setting mode
f750
: EASY key function selection
f751
to
f782
: Easy setting mode parameter 1 to 32
Up to 32 arbitrary parameters can be registered to easy setting mode.
Refer to section 4.5 for details.