E6581697
D-17
4
■
Shortcut key function (
=
)
This function allows you to register, in a shortcut list, parameters whose settings need to be changed frequently so
that you can read them out easily in a single operation.
The shortcut is usable in the frequency monitor mode only.
[Operation]
Set the parameter
to
, read out the setting of the parameter you want to register, and press and hold
down the EASY key for 2 seconds or more. The registration of the parameter in a shortcut list has been completed.
To read out the parameter, just press the EASY key.
■
Local/remote key function (
=
)
This function allows you to easily switch control devices (operation panel and terminal board) used to start and
stop operation and to set the frequency.
To switch between control device, set the parameter
to
, and then select the desired control device,
using the EASY key.
[When using the terminal board]
(
Remote mode
)
If
=
, no switching operation is required. The EASY lamp is in lights-out.
[When using the operation panel]
(
Local mode
)
Turn on the EASY key. The EASY lamp lights. Panel operation is possible.
Note) Please note that if set the parameter
to
in local mode, the panel operation state holds and it
becomes different from setting of
cmod
.
■
Peak hold function (
=
)
This function allows you to set peak hold and minimum hold triggers for parameters
,
,
,
and
, using the EASY key. The measurement of the minimum and maximum values set for
,
,
,
and
starts the instant when you press the EASY key after setting
parameter
to
.
The peak hold and minimum hold values are displayed in absolute values.
Summary of Contents for TOSVERT VF-MB1