E6581697
G-7
7
Assign one type of function to an output terminal
Terminal
symbol
Title
Function
Adjustment range
Default setting
RY-RC
Output terminal selection 1A
4 (Low-speed detection signal)
OUT
Output terminal selection 2A
6 (Output frequency
attainment signal)
FL
(A, B, C)
Output terminal selection 3
0 - 255
10 (Fault signal)
Note 2) When assigning 1 type of function to the RY-RC terminal, set only
.
Leave parameter
as the standard setting (
=
).
Note 3) When assigning 1 type of function to the OUT terminal, set only
.
Leave parameter
as the standard setting (
=
).
Assign two types of functions to the output terminal (RY-RC, OUT)
Terminal
symbol
Title
Function
Adjustment range
Default setting
RY-RC
Output terminal
selection 1A
4 (Low-speed detection
signal)
OUT
Output terminal
selection 2A
6 (Output frequency
attainment signal)
RY-RC
Output terminal
selection 1B
OUT
Output terminal
selection 2B
0 - 255
255 (Always ON)
0:
and
and
1:
or
and
2:
and
or
RY-RC, OUT
Output terminal logic
selection
3:
or
or
0
Note 4)
and
are active only when
=
: Logic output (default).
Function is inactive when
=
: Pulse train output is set.
Summary of Contents for TOSVERT VF-MB1