E6581697
F-110
6
[Parameter setting]
Title
Function
Adjustment range
Default setting
f710
Initial panel display selection
0
f720
Initial extension panel display
selection
0: Output frequency (Hz/free unit)
1: Output current (%/A)
2: Frequency command value (Hz/free unit)
3: Input voltage (DC detection) (%/V)
4: Output voltage (command value) (%/V)
5: Input power (kW)
6: Output power (kW)
7: Torque (%)
8: -
9: Motor cumulative load factor
10: Inverter cumulative load factor
11: PBR (Braking resistor) cumulative load
factor
12: Stator frequency (Hz/free unit)
13: VIA input value (%)
14: VIB input value (%)
15 to 17: -
18: Arbitrary code from communication
19: -
20: VIC input value (%)
21: Pulse train input value (kpps)
22: -
23: PID feedback value (Hz/free unit)
24: Integral Input power (kWh)
25: Integral Output power (kWh)
26: Motor load factor (%)
27: Drive load factor (%)
28: Drive rated current (A)
29: FM output value (%)
30: Pulse train output value (kpps)
31: Cumulative power on time (100 hours)
32: Cumulative fan operation time (100
hours)
33: Cumulative operation time (100 hours)
34: Number of starting (10000 times)
35: Forward number of starting (10000
times)
36: Reverse number of starting (10000
times)
37 to 39: -
40: Inverter rated current (Carrier
frequency corrected)
41 to 51: -
52: Frequency command value /
output frequency (Hz/free unit)
0
,
For details on
f710
/
f720
=
18
, see the Communications Function Instruction Manual.
Note: If
f720
=
18
setting, fixed value is displayed.