Torque Limit 1/2 Switching/Torque Limit 3/4 Switching
— Activating combinations of discrete input terminals
Torque Limit Switching
allow for the selection of a torque limit switching
profile as listed below.
34
35
36
37
PID Off
— Activation turns off
PID
control.
38
39
Pattern Run Selection 1
— Activation selects the configured
Pattern 1 Pattern Run
for operation. Deactivate to
remove the configured
Pattern 1 Pattern Run
.
40
41
Pattern Run Selection 2
— Activation selects the configured
Pattern 2 Pattern Run
for operation. Deactivate to
remove the configured
Pattern 2 Pattern Run
.
42
43
Pattern Run Selection 3
— Activation selects the configured
Pattern 3 Pattern Run
for operation. Deactivate to
remove the configured
Pattern 3 Pattern Run
.
44
45
Pattern Run Selection 4
— Activation selects the configured
Pattern 4 Pattern Run
for operation. Deactivate to
remove the configured
Pattern 4 Pattern Run
.
46
47
Pattern Run Continuation
— Initiates a continuation of the last
Pattern Run
from its stopping point.
48
49
Pattern Run Trigger
— Initiates the first
Preset Speed
of a
Pattern Run
and initiates each subsequent enabled
Preset Speed
with continued activations.
50
51
Forced Jog Forward
— Provides a forward-run signal for the duration of the activation (the status of the
F
and
R
to set the
Jog Run Frequency
and use
to select the
Jog Stop Method
.
52
53
Forced Jog Reverse
— Provides a reverse run signal for the duration of the activation (the status of the
F
and
R
to set the
Jog Run Frequency
and use
to select the
Jog Stop Method
.
54
55
Binary Bit 0
— Bit 0 – 7 may be set up as a speed/torque control register. Speed/torque settings may be applied to
this group of terminals in binary form. The required number of input terminals should be set to the respective
binary bit settings (0 – MSB). The
Frequency Mode
setting must be set to
Binary/BCD.
The gain and bias of the binary input may be set from the following path: Program
Frequency
Speed
Reference Setpoints
BIN
.
56
57
Binary Bit 1
— Used in conjunction with terminal setting 54/55 above.
58
59
Binary Bit 2
— Used in conjunction with terminal setting 54/55 above.
60
61
Binary Bit 3
— Used in conjunction with terminal setting 54/55 above.
62
63
Binary Bit 4
— Used in conjunction with terminal setting 54/55 above.
64
65
Binary Bit 5
— Used in conjunction with terminal setting 54/55 above.
66
67
Binary Bit 6
— Used in conjunction with terminal setting 54/55 above.
68
69
Binary Bit 7
— Used in conjunction with terminal setting 54/55 above.
Note:
NO/NC = Normally Open/Normally Closed.
Note:
Selection numbers are used when configuring the ASD via communications. They differentiate the Normally
Open and Normally Closed contact settings.
Table 8. (Continued) Discrete Input Terminal Assignment Selections and Descriptions.
Sel. No.
Terminal Selection Descriptions
NO NC
Torque Limit
Switching Terminal
Torque Limit Selection
#1
#2
0
0
1
0
1
2
1
0
3
1
1
4
1=Terminal Activated
The 1 – 4 settings of the torque limit switching
selections are performed at parameters
Summary of Contents for GX9
Page 2: ......
Page 3: ...Document Number 66893 001 March 2014 GX9 ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...iv GX9 ASD Installation and Operation Manual ...
Page 251: ...GX9 ASD Installation and Operation Manual 239 Figure 36 GX9 ASD 5 0 20 HP Enclosure ...
Page 252: ...240 GX9 ASD Installation and Operation Manual Figure 37 GX9 ASD 25 75 HP Enclosure ...
Page 253: ...GX9 ASD Installation and Operation Manual 241 Figure 38 GX9 ASD 100 200 HP Enclosure ...
Page 254: ...242 GX9 ASD Installation and Operation Manual Figure 39 GX9 ASD 250 400 HP Enclosure ...
Page 255: ...GX9 ASD Installation and Operation Manual 243 Figure 40 GX9 ASD 500 800 HP Enclosure ...
Page 256: ...244 GX9 ASD Installation and Operation Manual Figure 41 GX9 ASD 900 1200 HP Enclosure ...
Page 268: ......
Page 269: ......