170
GX9 ASD Installation and Operation Manual
Pattern Run Disposition
Program
Frequency
Pattern Run
This parameter sets the start condition of subsequent
Pattern Runs
after the
initial
Pattern Run
has been terminated or has completed its programming.
Settings:
0 — Pattern Run Canceled After Stop
1 — Pattern Run Continued After Stop
Direct Access Number — F521
Parameter Type —
Selection List
Factory Default —
Pattern Run
Canceled After Stop
Changeable During Run —
No
Pattern Run Group 1 Repeat Factor
Program
Frequency
Pattern Run
This parameter sets the number of times that the pattern defined in
Group 1
will be run.
Direct Access Number — F530
Parameter Type —
Numerical
Factory Default —
1
Changeable During Run —
No
Minimum — 1
Maximum — 255 (Infinite)
Units — Repetitions
Pattern Run Group 1 Selection 1
Program
Frequency
Pattern Run
This parameter allows the user to select 1 of 15 configured
Preset Speeds
as
the number
1
selection to be included in the
Group 1 Selection
.
Skip may be selected to ignore this
Selection
.
Setting
0 — Skip
1 – 15 Preset Speed Number
Direct Access Number — F531
Parameter Type —
Selection List
Factory Default —
Preset Speed 1
Changeable During Run —
No
Pattern Run Group 1 Selection 2
Program
Frequency
Pattern Run
This parameter allows the user to select 1 of 15 configured
Preset Speeds
as
the number
2
selection to be included in the
Group 1 Selection
.
Skip may be selected to ignore this
Selection
.
Setting
0 — Skip
1 – 15 Preset Speed Number
Direct Access Number — F532
Parameter Type —
Selection List
Factory Default —
Preset Speed 2
Changeable During Run —
No
Pattern Run Group 1 Selection 3
Program
Frequency
Pattern Run
This parameter allows the user to select 1 of 15 configured
Preset Speeds
as
the number
3
selection to be included in the
Group 1 Selection
.
Skip may be selected to ignore this
Selection
.
Setting
0 — Skip
1 – 15 Preset Speed Number
Direct Access Number — F533
Parameter Type —
Selection List
Factory Default —
Preset Speed 3
Changeable During Run —
No
Summary of Contents for GX9
Page 2: ......
Page 3: ...Document Number 66893 001 March 2014 GX9 ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...iv GX9 ASD Installation and Operation Manual ...
Page 251: ...GX9 ASD Installation and Operation Manual 239 Figure 36 GX9 ASD 5 0 20 HP Enclosure ...
Page 252: ...240 GX9 ASD Installation and Operation Manual Figure 37 GX9 ASD 25 75 HP Enclosure ...
Page 253: ...GX9 ASD Installation and Operation Manual 241 Figure 38 GX9 ASD 100 200 HP Enclosure ...
Page 254: ...242 GX9 ASD Installation and Operation Manual Figure 39 GX9 ASD 250 400 HP Enclosure ...
Page 255: ...GX9 ASD Installation and Operation Manual 243 Figure 40 GX9 ASD 500 800 HP Enclosure ...
Page 256: ...244 GX9 ASD Installation and Operation Manual Figure 41 GX9 ASD 900 1200 HP Enclosure ...
Page 268: ......
Page 269: ......