118
GX9 ASD Installation and Operation Manual
RX2 Input Point 1 Torque
Program
Torque
Setpoints
This parameter is used to set the gain and bias of the
RX2
terminal when the
RX2
terminal is used as the control input while operating in the
Torque
Control
mode.
Note:
The
Expansion IO Card Option 1
option board (P/N ETB003Z)
is required to use this terminal.
The bias and gain of the
RX
respectively.
RX2 Torque Control Setup
Perform the following setup to allow the system to receive
Torque Control
input at the
RX2
terminal:
• Program
Fundamental
Standard Mode Selection
Frequency Mode
RX2
.
• Program
Fundamental
Standard Mode Selection
Command Mode
Selection
Terminal Board
.
• Provide a
Run
command (F and/or R).
• Set
RX2 Input Point 1 Torque
).
• Set
RX2 Reference Point 1
) — the input analog signal level that
corresponds to the speed setting at
RX2 Input Point 1 Torque
.
• Set
RX2 Input Point 2 Torque
).
• Set
RX2 Reference Point 2
— the input analog signal level that
corresponds to the speed setting at
RX Input Point 2 Torque
.
• Provide a
Run
command (F and/or R).
Torque Control
is accomplished by establishing an associated
V/f
output
pattern for a given
RX2
level.
Once set, as the
RX2
voltage changes, the ASD output speed and/or torque will
vary in accordance with the above settings.
This parameter sets
RX2 Input Point 1 Torque
and is the output torque value
that is associated with the setting of
RX2 Reference Point 1
when operating in
the
Torque Control
mode.
This value is entered as -250% to +250% of the rated torque.
See the
Expansion IO Card Option 1
instruction manual (D/N 58685) for
more information on the function of this terminal.
Direct Access Number — F226
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — -250.00
Maximum — +250.00
Units — %
Torque Settings
Summary of Contents for GX9
Page 2: ......
Page 3: ...Document Number 66893 001 March 2014 GX9 ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...iv GX9 ASD Installation and Operation Manual ...
Page 251: ...GX9 ASD Installation and Operation Manual 239 Figure 36 GX9 ASD 5 0 20 HP Enclosure ...
Page 252: ...240 GX9 ASD Installation and Operation Manual Figure 37 GX9 ASD 25 75 HP Enclosure ...
Page 253: ...GX9 ASD Installation and Operation Manual 241 Figure 38 GX9 ASD 100 200 HP Enclosure ...
Page 254: ...242 GX9 ASD Installation and Operation Manual Figure 39 GX9 ASD 250 400 HP Enclosure ...
Page 255: ...GX9 ASD Installation and Operation Manual 243 Figure 40 GX9 ASD 500 800 HP Enclosure ...
Page 256: ...244 GX9 ASD Installation and Operation Manual Figure 41 GX9 ASD 900 1200 HP Enclosure ...
Page 268: ......