6
© 2007 - 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO167/207/237
SCANNER
6 - 21
[E] CIS home position sensor (S1)
Notes:
When installing the scan motor, be sure to
adjust the tension of the belt using the belt
tension jig. Also, be sure to take off the right
rear cover when performing the adjustment.
(
P.2-22 "[I] Right rear cover")
The adjustment procedure is as follows.
1. Temporarily fix screw A and B.
2. Hook the belt tension jig to the motor
bracket and frame.
3. The scan motor is pulled by the belt
tension jig. Fix screw A and then B
at the stopped position.
4. Remove the belt tension jig.
Fig. 6-21
Fig. 6-22
(1) Take off the original glass.
P.6-17 "[A] Original glass"
(2) Remove 1 screw and take off the CIS home
position sensor with the bracket.
Fig. 6-23
A
Scan motor
B
Scan motor
Belt tension jig
Bracket
CIS home position sensor