Fuel Stop Control Unit
(Groundsmaster 322-D/325-D only)
(Fig. 17)
The control unit (Fig. 17, Item 27) is a solid-state timing
device that controls a fuel stop solenoid for shutting the
engine off with the ignition key switch.
To check operation of the control unit and fuel stop
solenoid, listen for an audible “click” when the key is
turned to the OFF position (after having been in the RUN
position), and then once again approximately 7 to 15
seconds after the key switch has been turned off. The
“clicking” should is made by the solenoid (on back of
injection pump). These sounds signify that the system
is functioning properly
e le c trica lly
.
Detailed testing of the control unit, alone, is provided in
the chart that follows. These tests must be performed
with the control unit installed in the machine and con-
nected to the electrical system.
IMPORTANT: Testing the control unit by any other
method, especially when using a battery powered
meter or tester, may cause damage to the solid state
circuitry in the control unit.
Figure 17
Testing
Page 6 - 24
Groundsmaster
®
300 Series
Summary of Contents for Groundsmaster 328-D
Page 2: ......
Page 12: ...Torque Specifications Page 2 4 Rev A Groundsmaster 300 Series ...
Page 44: ...Troubleshooting Page 4 16 Groundsmaster 300 Series ...
Page 45: ...Groundsmaster 300 Series Page 4 17 Troubleshooting ...
Page 171: ...Groundsmaster 300 Series Page 6 25 Testing ...
Page 220: ...Repairs Page 7 24 Groundsmaster 300 Series ...
Page 320: ...Troubleshooting Troubleshooting Page 11 4 Groundsmaster 300 Series ...
Page 348: ...Troubleshooting Troubleshooting Page 12 4 Groundsmaster 300 Series ...
Page 379: ...Troubleshooting Groundsmaster 300 Series Page 13 3 Troubleshooting ...
Page 400: ...This page is blank ...
Page 401: ...This page is blank ...