17. Put the commutator cover on top of the commutator
ring with the flat surface towards the commutator (Fig.
79). Align the screw holes in the cover, with the screw
holes in the drive plate.
Figure 79
18. Screw the eleven hex socket head cap screws
loosely into the metering package (Fig. 80).
NOTE: The commutator ring must be concentric with the
drive plate within 0.005 in. (0.127 mm) total indicator
reading AFTER tightening the eleven hex socket head
cap screws. The next two procedures are a method of
achieving the concentricity.
19. Put the metering ring on a hard flat surface. Put the
assembled metering package into the metering ring with
the commutator cover down, so the drive plate is par-
tially out of the metering ring (Fig. 81). (A suitable wood
block under the metering package will hold it in this
position.) Put one piece of 0.007 in. (0.18 mm) shim
stock approximately 0.5 in. (12 mm) wide and 1.5 in.
(38 mm) long between the metering ring and drive plate
in three places approximately equal distance around the
outside diameter of the drive plate.
Figure 80
Figure 81
Groundsmaster
®
300 Series
Page 8 - 41
Repairs
Summary of Contents for Groundsmaster 328-D
Page 2: ......
Page 12: ...Torque Specifications Page 2 4 Rev A Groundsmaster 300 Series ...
Page 44: ...Troubleshooting Page 4 16 Groundsmaster 300 Series ...
Page 45: ...Groundsmaster 300 Series Page 4 17 Troubleshooting ...
Page 171: ...Groundsmaster 300 Series Page 6 25 Testing ...
Page 220: ...Repairs Page 7 24 Groundsmaster 300 Series ...
Page 320: ...Troubleshooting Troubleshooting Page 11 4 Groundsmaster 300 Series ...
Page 348: ...Troubleshooting Troubleshooting Page 12 4 Groundsmaster 300 Series ...
Page 379: ...Troubleshooting Groundsmaster 300 Series Page 13 3 Troubleshooting ...
Page 400: ...This page is blank ...
Page 401: ...This page is blank ...