Service and Repairs
Battery Service
The battery is the heart of the electrical system. With
regular and proper service, battery life can be extended.
Additionally, battery and electrical component failure
can be prevented.
Note:
Battery information for all Groundsmaster
322/325 machines and Groundsmaster 345 machines
with serial number below 21000000 is included in Chap-
ter 6.
Electrolyte Specific Gravity
Fully charged: 1.265 corrected to 80
o
F (26.7
o
C)
Discharged: less than 1.240
Battery Specifications Groundsmaster 328–D
BCI Group 24
660 Amp Cranking Performance at 0
o
F (–17.8
o
C)
110 Minute Reserve Capacity at 80
o
F (26.7
o
C)
Battery Specifications Groundsmaster 345
BCI Group 24
420 Amp Cranking Performance at 0
o
F (–17.8
o
C)
67 Minute Reserve Capacity at 80
o
F (26.7
o
C)
when working with electrolyte. Charge
the battery in a well ventilated so gases
produced while charging can dissipate.
battery; do not smoke. Nausea may
result if the gases are inhaled. Unplug
leads from battery posts.
CAUTION
Wear safety goggles and rubber gloves
Since the gases are explosive, keep open
flame and electrical spark away from the
charger from electrical outlet before con-
necting to, or disconnecting charger
Inspection, Maintenance and Testing
1. Perform the following inspection and maintenance
tasks:
A. Check for cracks caused by overly tight or loose
hold–down clamp. Replace battery if cracked and
leaking.
B. Check battery terminal posts for corrosion. Use
a terminal brush to clean corrosion from the battery
terminal posts.
IMPORTANT: Before cleaning the battery, tape or
block the vent holes to the filler caps and make sure
the caps are on tightly.
COVER SEAL
FILLER CAPS
CORRECT
LEVEL
WATER
CAP TUBES
Figure 14
C. Check for signs of wetness or leakage on the top
of the battery which might indicate a loose or mis-
sing filler cap, overcharging, loose terminal post or
overfilling. Also, check the battery case for dirt and
oil. Clean the battery with a solution of baking soda
and water, then rinse it with clean water.
D. Check that the cover seal is not broken away.
Replace the battery if the seal is broken or leaking.
E. Check the electrolyte level in each cell. If the lev-
el is below the tops of the plates in any cell, fill all
cells with
distilled
water to the bottom of the cap
tubes. Charge at 15 to 25 amps for 15 minutes to al-
low sufficient mixing of the electrolyte.
Electrical System (Rev. G)
Page 6A – 12
Groundsmaster 300 Series
Summary of Contents for Groundsmaster 328-D
Page 2: ......
Page 12: ...Torque Specifications Page 2 4 Rev A Groundsmaster 300 Series ...
Page 44: ...Troubleshooting Page 4 16 Groundsmaster 300 Series ...
Page 45: ...Groundsmaster 300 Series Page 4 17 Troubleshooting ...
Page 171: ...Groundsmaster 300 Series Page 6 25 Testing ...
Page 220: ...Repairs Page 7 24 Groundsmaster 300 Series ...
Page 320: ...Troubleshooting Troubleshooting Page 11 4 Groundsmaster 300 Series ...
Page 348: ...Troubleshooting Troubleshooting Page 12 4 Groundsmaster 300 Series ...
Page 379: ...Troubleshooting Groundsmaster 300 Series Page 13 3 Troubleshooting ...
Page 400: ...This page is blank ...
Page 401: ...This page is blank ...