Priming After Transmission Overhaul Or Replacement
Use the following procedures to prime the hydraulic
system whenever the Sundstrand Transmission is over-
hauled or replaced:
1. Pour a quantity of transmission oil into the transmis-
sion before mounting it to the machine.
2. Fill a new filter with fresh, clean oil and install it onto
the transmission.
3. Remove the dipstick from the pipe nipple in the
differential assembly and add oil to the proper level.
4. Start the engine and operate the traction and lift
system controls for approximately five minutes. Then
turn the engine off.
5. Allow the machine to stand idle for approximately two
minutes, remove the dipstick and check the oil level. If
the oil level is too high, drain the system until it is at the
correct level. Add oil if the fluid level is too low.
Repairs