Testing
This section will define components, and the tests that
can be performed on those components, when those
parts are disconnected from the electrical system.
For accurate resistance and/or continuity checks, elec-
trically disconnect the component being tested from the
circuit (e.g. unplug the seat switch connector before
doing a continuity check).
NOTE: Electrical troubleshooting of any 12 Volt power
connection can also be performed through voltage drop
tests without disconnection of the component.
When testing electrical components for con
tinuity with a volt-ohm meter or continuity
tester, make sure that power to the circuit has
been disconnected.
CAUTION
Ignition Key Switch (Fig. 5)
The circuitry of the ignition switch is shown in the charts.
With the use of a continuity tester, the switch functions
may be tested to determine whether all circuits are being
completed while the key is moved to each position.
POSITION
CONTINUITY AMONG TERMINALS
Y
A
1. OFF
NONE
X
B
I
S
Y
A
2. ON
B
+
I
+
A
X
+
Y
X
B
I
S
Y
A
3. START
B
+
I
+
S
X
B
I
S
Figure 5
Testing
Page 6 - 18
Groundsmaster
®
300 Series
Summary of Contents for Groundsmaster 328-D
Page 2: ......
Page 12: ...Torque Specifications Page 2 4 Rev A Groundsmaster 300 Series ...
Page 44: ...Troubleshooting Page 4 16 Groundsmaster 300 Series ...
Page 45: ...Groundsmaster 300 Series Page 4 17 Troubleshooting ...
Page 171: ...Groundsmaster 300 Series Page 6 25 Testing ...
Page 220: ...Repairs Page 7 24 Groundsmaster 300 Series ...
Page 320: ...Troubleshooting Troubleshooting Page 11 4 Groundsmaster 300 Series ...
Page 348: ...Troubleshooting Troubleshooting Page 12 4 Groundsmaster 300 Series ...
Page 379: ...Troubleshooting Groundsmaster 300 Series Page 13 3 Troubleshooting ...
Page 400: ...This page is blank ...
Page 401: ...This page is blank ...