Gear Case Removal and Installation (Fig. 41, 42)
Removing Gear Case and Drive Pulley
1. Lower the cutting unit, shut engine off and engage the
parking brake.
2. Remove shroud (Item 20) covering universal drive
shaft. Disconnect drive shaft from gear case. Remove
belt covers from top of cutting unit.
DANGER
Do not start the engine and engage the P.T.O.
when the P.T.O. shaft is not connected to the
gear case. If engine is started and the P.T.O.
shaft is allowed to rotate, serious injury could
result.
3. Loosen belt tension and remove belt from gear case
pulley.
4. Remove flange nuts and carriage bolts securing gear
case mount plate (Item 22) to cutting unit and remove
plate and gear case.
5. Remove the set screws (Item 28) from the taper lock
bushing (Item 27). Install one setscrew into the hole that
is threaded on the side of taper lock. Tighten the set-
screw until the taper lock is loose from the inside of the
pulley hub.
NOTE: Only one setscrew is used to loosen the
taper lock.
6. Slide the gear case pulley (Item 26) and taper lock
(Item 27) off of the gear case output shaft. Account for
the woodruff key (Item 24) that positions the pulley on
the shaft, and remove the setscrew from the side of the
taper lock.
7. Remove gear case from mount plate and remove
brackets (Item 18) from gear case.
Figure 41
Repairs
Page 12 - 26
Groundsmaster
®
300 Series
Summary of Contents for Groundsmaster 328-D
Page 2: ......
Page 12: ...Torque Specifications Page 2 4 Rev A Groundsmaster 300 Series ...
Page 44: ...Troubleshooting Page 4 16 Groundsmaster 300 Series ...
Page 45: ...Groundsmaster 300 Series Page 4 17 Troubleshooting ...
Page 171: ...Groundsmaster 300 Series Page 6 25 Testing ...
Page 220: ...Repairs Page 7 24 Groundsmaster 300 Series ...
Page 320: ...Troubleshooting Troubleshooting Page 11 4 Groundsmaster 300 Series ...
Page 348: ...Troubleshooting Troubleshooting Page 12 4 Groundsmaster 300 Series ...
Page 379: ...Troubleshooting Groundsmaster 300 Series Page 13 3 Troubleshooting ...
Page 400: ...This page is blank ...
Page 401: ...This page is blank ...