A: the regression point setting error. Into the ―Regression Point Setting‖ interface, set
the regression point as mechanism origin point.
Q: the setting of power back to origin is close, after power, X, Y still automatically
moving.
A: the regression point setting error. Into the ―Regression Point Setting‖ interface, set
the regression point as mechanism origin point.
6.2 The Laser Light Question
Q: Long light after power on.
A: view the enable signal of laser power is wiring, and see the jumpers of interface
broad DIR3 and DIR4, check whether they e keep the consistency.
Q: When the light power intensity is big, the idemitsu is small; when the light power
intensity is small, the idemitsu is big.
A: the PWM polarity setting error, into the button polarity setting interface, changes the
PWM polarity.
Q: PWM frequency is correct, light power intensity can be changed by line within 10% -
60%.
A: check the laser power supply model, it’s 5.5 voltage, not 3.3V.
Q: Water protection invalid.
A: check the laser type, there are 3 types: 0 is CO
2
glass
tube; 8 is coherent glass tube;
16 is RF tube. If the laser type is correct, please check the water protection directly
shorted.
6.3 The PC Connection Question
The Questions:
Reading the parameters, can’t open the port.