泰智科技
Shenzhen Topwisdom Technology Co., Ltd
18
sensor input
4
IN-4
Y upper limit, axis movement to the max coordinate limit sensor
input
5
IN-5
Y origin limit, axis movement to the minimum coordinate(0)limit
sensor input
6
XGND
External 5V power source grounding (output)
Z, U axis limit interface J7
Pin
Definition
1
EX 5V
External 5V power source positive (output)
2
IN-7
Z origin limit, axis movement to the minimum coordinate(0)limit
sensor input
3
IN-8
U origin limit, axis movement to the minimum coordinate(0)limit
sensor input
4
IN-9
Opening protection signal input
5
IN-10
Foot switch signal input
6
XGND
External 5V power source grounding (output)
The general input interface
Input interface J4
Pin
Definition
1
EX 5V
External 5V power source positive (output))
2
IN-11
U axis upper limit switch input
3
IN-12
U axis lower limit switch input
4
IN-13
V origin limit, axis movement to the minimum coordinate(0)limit
sensor input
5
XGND
External 5V power source grounding (output)
When using the single laser control, the water protection signal of another laser must
be shorted with XGND, otherwise, the machine don’t work.