6.1 Power-on Reset Question
Q: the system does not reset, buttons no response, and LCD no display.
A: the system reset error, the solution is:
First, click the ―Emergency Stop‖ on the panel, and check the button normal.
Second, check the external 5V and internal 5V are within the normal.
Q: opening, the X, Y axis not move, the LCD display the main interface, can manual
move the axis.
A: the power back to origin error. Into the ―Power back to Origin‖ interface, set the X, Y
axis as Opening.
Q: opening, the X, Y axis returns the origin, the LCD still shows ―system initialization‖.
A: the power back to origin error. Into the ―Power back to Origin‖ interface, set the Z, U
axis as Close.
Q: opening, X, Y slow-move a short distance, not reach to the limit point, and complete
the reset.
A: the Limit Polarity error. Into the ―Limit Polarity‖ interface, change the X, Y polarity.
Q: opening X, Y move to the opposite direction of limit switch,
A: the direction polarity error. Into the ―Direction Polarity‖ interface, change the X, Y
polarity.
Q: button moving, X, Y moving direction is opposite to the button moving.
A: the button polarity error. Into the ―Button Polarity‖ interface, change the X, Y polarity.
Q: after the completion of reset, X, Y fast automatically moving.