泰智科技
Shenzhen Topwisdom Technology Co., Ltd
86
4 0 0
User Set
9 D o o r P o l a r i t y
.
8 F e e d i n g D e l a y m s
.
(
)
1 0 O U T 7 P l a r i t y
.
o
1 1 M i n A c c m m s 2
.
(
/
)
ESC
Save
5 0 0
0
P o s i t i v e
2 0 1 4 0 3 1 0 1 1 0 0
-
-
:
1 2 W a t e r P r o t e c t
.
O p e n
Fig. 5-26
Press ―Up/Down‖ key to select the items, press ―Choose‖ key to change the Combo
Box, press the ―Number‖ key to edit the value, press ―Enter‖ to save the setting, press
―ESC‖ to back.
Cover Protect:
When it is ON, system will detect the cover protect switch signal.
While the signal is valid it would stop the working.
Key Move Continue:
When it is ON, Press the ―UP/Down/Left/Right‖ arrow key or
―Z+/Z-/U+/U-‖ to move the axis, Release these key to stop moving.
Key Move Dist.(mm):
When the ―Key Move Continue‖ is OFF, the
―UP/Down/Left/Right‖ arrow key or ―Z+/Z-/U+/U-‖ to move the axis with the
distance set by the ―Key Move Dist‖.
Return point:
Origin, None Set Point. The position which the system back to while
work is finishing.
Laser On/Off Delay:
Turn this ON for take the Laser On/Off Delay effect.
Back Speed (mm/s):
The homing speed.
Pulse Time (ms):
The time of laser is on when ―Pulse‖ is press.
Feeding Delay (ms):
The delay time after feeding.
Door Polarity:
Change the parameter while the Cover Protect switch working in
wrong way.
OUT7 Polarity:
Change the OUTPUT7 electrical level. Negative is low level.
Positive is high level.
Min Acc(mm/s2):
The min acceleration for start moving or stop moving. The less
this value, the smoother the movement, the longer the working time. Normally, it is
set to400mm/s2, if a shorter work time is demanded, set the value no less than
850 mm/s2(According to the actual machine to set this value).