泰智科技
Shenzhen Topwisdom Technology Co., Ltd
52
be shown in the status bar at the bottom, the parameters cannot be written into the
machine.
Clear:
Besides the drop-down box option, the rest of the parameter value will be set to
null, which is no parameter values.
※
Topwisdom software uses serial ports for writing and reading, therefore, once a kind
of software is using a serial port, other software cannot use this serial port.
Equipment Type:
type of the used machine. There are mainly general engravers and
brand engravers.
Open_cover safeguard:
If Yes is selected, whenever the cover is open by user,
machine will start the safety protective measures, to pause working. In the case of
equipment with safety protection, which do not use the open protection, user can also
will set the Open_cover safeguard parameter as "No". Such as test equipment, test
process, but this operation must be performed by the professionals, generally don't
recommend customers to use.
Laser Type:
Select proper laser device type according to the laser device used by the
machine.
PWM Frequency:
I.e., the power intensity frequency of the laser tube, this value
differs according to different types of the laser tubes; please consult the instructions for
the laser tube for details.
Least Light:
The min. duty ratio supported by the engraver.
Most Light:
The max. duty ratio supported by the engraver.
Laser Open/Close Delay:
the delay parameter set to avoid the uneven edges of the
first Outline and the last Outline when the laser is on or off.
Laser on Delay:
Because it takes a short period to start the laser, in order to make the
power and the laser head be started synchronously, the laser device is started before
the laser head. I.e., the Laser On Delay.
Laser off Delay:
Because it takes another period of time to shut off the laser after
receiving the instruction, in order to avoid excessive engraving, the laser is shut off in
advance.
Least Pulse Width:
The min. pulse width to be recognized by the laser device.