Parameter description:
Out Rows:
The rows of the output shape.
Out Columns:
The Columns of the output shape. By defaut, the row and column is 1,it
means the shape will be processed once.
Row Interval (mm):
The interval size of row. The unit is mm.
Columns Interval (mm):
The interval size of column. The unit is mm.
FeedingTimes:
After finish one process, the machine can feed once. The feeding
times parameter determines how many time it will feed.
FeedingPerSize(mm):
the feeding length.
Feeding delay:
The delay time after feeding. The Unit is second.
Attention: These parameters above are applied to array process or repeat process.
Here, the row and the column is array parameters. If row is 2 and column is 1, then
2X1 array work file will be outputted. The row interval determines the distance between
two rows. The columns interval determines the distance between two columns.
Feeding Times, FeedingPerSize, Feeding delay is applied to the machine with feeding
equipment. Feeding Times is repeat work parameters. Click the ―>>‖ button for more
array setting. As shown in figure below, it can set the table size—table width and length,
work start position, row, column, row interval, column interval. Click the Import button
or Auto-filled button to preview. Click ok to save configure.