Operating Instructions
69
Switching from Electric to Diesel
Units equipped with the SMARTPOWER option only.
If the Electric to Diesel Auto-Switch Enabled feature in
Guarded Access is set YES then the unit will automatically
switch to Diesel Mode operation when standby power is turned
off or is no longer available.
If the Electric to Diesel Auto-Switch Enabled feature in
Guarded Access is set NO and standby power is disconnected
or fails, the unit will not automatically switch to Diesel mode.
This is primarily designed to prevent unauthorized diesel
engine starts when the truck is indoors or on a ferry where
engine operation is strictly prohibited. If the Electric to Diesel
Auto-Switch Enabled feature in Guarded Access is set NO then
the prompt screen (Figure 61) will appear when standby power
is turned off or is no longer available.
Figure 61: Standby Power is Off
If YES is selected then the display will briefly show the screen
in Figure 62.
Figure 62: Yes Selected
ELECTRIC STANDBY NOT DETECTED
DO YOU WISH TO SWITCH TO
DIESEL?
YES
NO
ON
OFF
PROGRAMMING DIESEL MODE
PLEASE WAIT
ON
OFF
Summary of Contents for Precedent S-600
Page 9: ...6 ...
Page 11: ...Introduction 8 ...
Page 15: ...EPA Emission Control System Warranty Statement 12 ...
Page 38: ...Unit Description 35 Figure 13 SR 4 Controller ...
Page 39: ...Unit Description 36 ...
Page 43: ...Remote Status Display Optional 40 ...
Page 127: ...Operating Instructions 124 ...
Page 143: ...Optional Rear Remote Control Panel 140 ...
Page 179: ...Alarm Codes 176 ...
Page 197: ...Warranty 194 ...
Page 209: ...Maintenance Inspection Schedule 206 ...
Page 213: ...Serial Number Locations 210 ...
Page 217: ...214 ...