Specifications
192
Standby Power Cord Requirements
Supply Circuit Breaker: 12 HP Motor 230/3/60
70 amps
12 HP Motor 460/3/60
40 amps
19 HP Motor 460/3/60
60 amps
Extension Cord Size:
12 HP Motor 230/3/60
8 AWG Power Cable, up to 50-foot length
12 HP Motor 230/3/60
6 AWG Power Cable, 75-foot length
12 HP Motor 460/3/60
10 AWG Power Cable, up to 75-foot length
19 HP Motor 460/3/60
8 AWG, Power Cable, up to 75-foot length
Electric Fuel Heater (Optional)
Electric Fuel Heater:
Resistance
Current Draw at 12.5 Vdc
Internal Thermostat Minimum Closing Temp.
Internal Thermostat Maximum Opening Temp.
0.9 to 1.1 ohms
11.4 to 13.9 amps
30 F (-1 C)
75 F (24 C)
2FH/2HP Fuse
20 amps