Specifications
187
Electrical Components
NOTE: Disconnect components from unit circuit to check resistance.
Component
Current Draw (Amps)
at 12.5 Vdc
Resistance—Cold
(Ohms)
Glow Plugs (4) Each
4.5
2.8
Pilot Solenoid
0.7
17.0
Electronic Throttling Valve:
Coil A (Red [EVA] and Blue [EVB] Wires)
Coil B (Black [EVC] and White [EVD] Wires)
—
—
20 to 35
20 to 35
Hot Gas Bypass Valve (if used)
1.1
11.1
Starter Motor
350-475*
* On-the-engine cranking check. Bench test is approximately 140 amps.
S-600 AC Generator
Low Engine Speed (1250 rpm) Output
High Engine Speed (2050 rpm) Output
210 Vac at 60 Hz
345 Vac at 90 Hz