Operating Instructions
54
The Standard Display
The Standard Display is the default display that appears if no
other display function is selected. The Standard Display shows
the box temperature and setpoint. The box temperature is that
measured by the controlling sensor, usually the return air
sensor. The box temperature in Figure 36 is 35.8 F (2.1 C)
with a 35 F (1.7 C) setpoint.
Figure 36: Standard Display
The down-pointing arrow at the left side of the
display shows the unit is cooling. If the arrow
were pointing upward the unit would be heating.
The unit is running in Cycle Sentry Mode as
shown by the Cycle Sentry Icon in the upper right
corner of the display. If the Cycle Sentry icon is
not present, the unit would be running in
Continuous Mode.
The USB Icon in the upper left corner of the
display will appear when a USB Flash Drive is
connected to the Flash Drive Only USB Port on
the unit control panel or a PC computer is
connected to the PC Only USB Port on the Unit
Control Panel.
Pressing the left soft key allows the user to change the
SETPOINT, and pressing the right soft key accesses the MAIN
MENU. The other two soft keys access the GAUGES menu
and the SENSORS menu.
NOTE: The functions of the GAUGES and SENSORS soft
keys may be re-assigned to better suit customer requirements.
The GAUGES and SENSORS functions are always available
from the Maintenance Menu.
ON
OFF
MENU
35
°F
35
SET
SENSORS
GAUGES
POINT
.8
Summary of Contents for Precedent S-600
Page 9: ...6 ...
Page 11: ...Introduction 8 ...
Page 15: ...EPA Emission Control System Warranty Statement 12 ...
Page 38: ...Unit Description 35 Figure 13 SR 4 Controller ...
Page 39: ...Unit Description 36 ...
Page 43: ...Remote Status Display Optional 40 ...
Page 127: ...Operating Instructions 124 ...
Page 143: ...Optional Rear Remote Control Panel 140 ...
Page 179: ...Alarm Codes 176 ...
Page 197: ...Warranty 194 ...
Page 209: ...Maintenance Inspection Schedule 206 ...
Page 213: ...Serial Number Locations 210 ...
Page 217: ...214 ...