Specifications
186
* When the compressor is removed from the unit, oil level should be noted or the oil removed from the
compressor should be measured so that the same amount of oil can be added before placing the
replacement compressor in the unit.
Refrigeration System
Electrical Control System
Low Voltage
12.5 Vdc
High Voltage
200 - 210 Vac from AC generator at engine low speed
345 Vac from AC generator at engine high speed
Battery
One, group C31, 12 volt, (950 CCA recommended for
operation below -15 F [-26 C])
Fuses
See “Base Controller Fuses” on page 101, and other fuses
on pages 105 and 107.
Battery Charging
12 volt, 37 amp, brush type, Thermo King Alternator
Voltage Regulator Setting
13.95 to 14.35 volts @ 77 F (25 C)