Operating Instructions
52
The new language is confirmed, and then the Standard Display
will appear in the new language as shown in Figure 31. The
unit is ready to run.
Figure 31: Standard Display, New Language
If Log Alarms are Present
Log Alarms are indicated for 60 seconds each time the unit is
turned on. This level of alarm serves as a notice to take
corrective action before a problem becomes severe.
Maintenance items such as maintenance hourmeter time-outs
are log alarms. The Temperature Watch screen is not disabled
if only log alarm(s) are active.
If log alarm(s) are present the Log Alarm notice shown in
Figure 32 will appear on the display for 60 seconds. The
remote indicator alarm light (if installed) will also be on during
this period. After 60 seconds the Standard Display will appear
and the remote indicator alarm light will go off. Pressing the
EXIT soft key (Figure 32) will return to the Standard Display
immediately.
Figure 32: Log Alarms Active
NOTE: The Alarm Icon does not appear on startup with
log alarms present.
When the unit is ready to run the Standard Display
appears(Figure 33).
ON
OFF
LOG ALARMS ACTIVE
GO TO MENU TO VIEW
EXIT
Summary of Contents for Precedent S-600
Page 9: ...6 ...
Page 11: ...Introduction 8 ...
Page 15: ...EPA Emission Control System Warranty Statement 12 ...
Page 38: ...Unit Description 35 Figure 13 SR 4 Controller ...
Page 39: ...Unit Description 36 ...
Page 43: ...Remote Status Display Optional 40 ...
Page 127: ...Operating Instructions 124 ...
Page 143: ...Optional Rear Remote Control Panel 140 ...
Page 179: ...Alarm Codes 176 ...
Page 197: ...Warranty 194 ...
Page 209: ...Maintenance Inspection Schedule 206 ...
Page 213: ...Serial Number Locations 210 ...
Page 217: ...214 ...