Service Manual for the Thermador Pro Grand Next Generation 48-Inch Natural Gas and LP Gas Ranges, Models:
PRG486JDG/01, PRL486JDG/01
58300000159722_ARA_EN_D
Page 66 of 92
6.9.2
Meat Probe Receptacle Components – Removal and
Replacement
For the meat probe receptacle components (not the probe),
access is required from both the front and side of the range.
The meat probe measures the meat temperature and turns off oven
when the defined temperature is reached.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing these components.
Figure 98: Meat Probe Receptacle Components
1
Nut
2
Lockwasher
3
Cover
4
Oven cavity (shown for reference)
5
Receptacle for probe (probe not shown)
1. Follow all safety precautions and steps in
2. Remove oven trays.
3. Remove the backguard (see
4. Remove maintop components (see
page
5. For the large oven, remove the right side panel. For the small
oven, remove the left side panel (see
page
6. Remove the oven door (see
7. From inside the oven cavity, use a wrench to remove and retain
the nut and lockwasher, and then remove the cover (see
Figure 99).
Figure 99: Removing the Nut and Lockwasher